Understanding Fan Requirements for Fluidized Bed Boilers
Fluidized bed boilers have distinct requirements for the handling of air and flue gas at various stages of their operational process.
Primary air fans, secondary air fans, and induced draft fans operate under different conditions in terms of airflow volume, pressure, and temperature. When selecting equipment, it is essential to carefully consider the specific operational requirements for each type of fan; they cannot be treated as interchangeable, general-purpose units.
For a 36 t/h fluidized bed boiler project in Inner Mongolia, for instance, SIMO Blower supplied three centrifugal fans, each tailored to meet the specific operational demands of its respective process stage.

Centrifugal Fan Selection and Performance Data for the Project
Based on their respective installation locations, these three fans have been assigned different performance parameters.
| Fan Type | Airflow | Total Pressure | Temperature | Motor Power |
|---|---|---|---|---|
| Primary Air Fan | 33,667 m³/h | 13,500 Pa | 20°C | 200 kW |
| Secondary Air Fan | 27,504 m³/h | 10,705 Pa | 20°C | 132 kW |
| Induced Draft Fan | 105,295 m³/h | 10,047 Pa | 150°C | 400 kW |
Primary Air Fan: High-Pressure Air Supply
The design parameters for this primary air fan are as follows: air volume of 33,667 m³/h and a total pressure of 13,500 Pa.
Specific configuration:
● Model: 1750SWB21D
● Quantity: 1 unit
● Motor Power: 200 kW
● Operating Temperature: 20°C
● Rotation Direction: Counter-clockwise (left-hand), 90°
Pressure requirement is a critical parameter for the selection of this fan. When evaluating the fan, the resistance of the associated air supply system must be fully taken into account.
Secondary Air Fan: Dedicated Air Supply Function
The secondary air fan has a rated air volume of 27,504 m³/h and a total pressure of 10,705 Pa.
Its specifications are as follows:
● Model: 1550SWB21D
● Quantity: 1 unit
● Motor Power: 132 kW
● Operating Temperature: 20°C
● Rotation Direction: Clockwise (Right-hand), 90°
Although both the primary and secondary air fans are used to supply combustion air, they operate at different duty points. Consequently, their performance must be evaluated separately, and their respective fan configurations must be determined accordingly.
Induced Draft (ID) Fan: High-Temperature Flue Gas Extraction
This induced draft fan is designed to handle high air volumes and is suitable for flue gas temperatures of 150°C.
Key technical specifications are as follows:
● Model: 1950SWB28D
● Quantity: 1 unit
● Airflow: 105,295 m³/h
● Total Pressure: 10,047 Pa
● Operating Temperature: 150°C
● Motor Power: 400 kW
● Rotation Direction: Clockwise (Right-hand), 180°
The impeller is constructed from Q420 steel and features a wear-resistant hardfacing (weld overlay).
Compared to the two combustion air fans, this induced draft fan requires special attention regarding its high-temperature operating conditions, the selection of impeller material, and its wear resistance.
Why should boiler fans be selected on an individual basis?
Applying the same selection criteria to all fans within a boiler system can lead to an inefficient or inappropriate equipment configuration.
The following factors must be evaluated separately for each fan:
Airflow: The required gas flow rate varies for each fan depending on its specific position within the process flow.
Pressure: System resistance differs between the air supply path and the flue gas exhaust path.
Temperature: The specified operating temperatures for components such as combustion air fans and induced-draft (ID) fans differ.
Materials and Structural Requirements: The material used for the impeller of an induced-draft fan, as well as any wear-resistant treatments applied, must be determined based on the specific operating conditions.
Drive Configuration: The motor power must be matched to the performance characteristics and operating conditions of the selected fan.
Considering these factors collectively helps ensure that every fan in the boiler system is configured appropriately for its intended function.
Auxiliary Equipment and Maintenance Considerations
Fan selection extends beyond aerodynamic performance alone. During the development of project technical specifications, structural details and auxiliary equipment must also be taken into account.
The induced draft (ID) fan used in this project is equipped with an access door, a DN50 drain connection (fitted with an isolation valve), and a packed-gland shaft seal.
The impeller features a wear-resistant hardfacing overlay; furthermore, the selected fan package includes the necessary auxiliary equipment and monitoring devices.
These details form part of the equipment configuration and maintenance considerations for this specific application.
Customized Boiler Fan Solutions from SIMO Blower
For this 36 t/h fluidized bed boiler project, SIMO Blower supplied three centrifugal fans, designed for primary air, secondary air, and induced draft applications.
This project underscores the importance of evaluating each fan based on its specific requirements for airflow, pressure, temperature, and structural design.
SIMO specializes in providing customized centrifugal fan solutions for fluidized bed boilers, industrial combustion air supply systems, and flue gas extraction applications.
Does your boiler project require primary air fans, secondary air fans, or induced draft fans?
Please provide us with your boiler capacity, required airflow, pressure, temperature, and operating conditions. Our team will assist you in evaluating and determining the optimal fan configuration for each stage of your process.